Browse by products

Browse by products

EXHEx-proof housing

MARKETS

CERTIFICATIONS

DESCRIPTION

The EXH housings are made with strong Anticorodal aluminium die-cast alloy of AISi Mg EN AB- 42000 group.

EXHC

The cylindrical body of the EXHC housing (210mm diameter and 400mm length) is closed on opposite sides by two 12 mm thick flanges. The housing is supplied with two holes for the 3/4" NPT cable glands. The camera housing is equipped with heater and optional sunshield.

EXHD

Ex-proof housing with the same specifications as the EXHC series but fitted with a patented device for the protection of the glass which gives clear vision in dirty environments.

KEY FEATURES

Designed to meet the strictest international standards and to operate in hazardous areas

Solid, non corrosive die-cast aluminium construction

2 holes for cable glands 3/4" NPT

Environment temperature:ᅠ ᅠ-40°C/+50°C (-40°C/+122°F) with reinforced heater

TECHNICAL DATA

General
  • Non-corrosive die-cast aluminium (anticorodal)
  • Epoxy powder painted with orange peel effect, RAL7032
Mechanical
  • 2 holes for cable glands 3/4" NPT
  • External dimensions:
  • EXHC Ø 210mmx427.5mm (8.2x16.8in)
  • EXHD Ø 250x573.5mm (9.8x22.6in)
  • Internal dimensions:
  • EXHC Ø 180x380mm (7x14.9in)
  • EXHD Ø 180x460mm (7x18.1in)
  • Internal usable area:
  • EXHC 100x100x280mm (3.9x3.9x11in)
  • EXHD 100x100x280mm (3.9x3.9x11in)
  • Glass window:
  • EXHC Ø 114mm (4.5in)
  • EXHD 70x56mm (2.7x2.2in)
  • Unit weight:
  • EXHC 15kg / 33lb
  • EXHD 24kg / 52.9lb
  • Glass protection device:
  • Glass protection device:ᅠ ᅠØ 250x140mm (9.8x5.5in)
  • Mylar film 80mm (3.1in) wide and 18m (59ft) length, 350 shifting steps, marks printed on the last 50cm (19in)
Electrical
  • Reinforced heater:ᅠ ᅠTon 15°C±4°C (59°F±7°F),ᅠ ᅠToff 22°C±3°C (72°F±5°F)
  • 3 resistors in the housing, consumption 60W max
  • Glass protection device:
  • 24Vac,ᅠ ᅠpower consumptionᅠ ᅠ2Wᅠ ᅠmax
  • Devices to install inside the housing
  • Camera equipped with lens with max total power of 20W
  • Voltageᅠ ᅠmax.ᅠ ᅠ24Vacᅠ ᅠorᅠ ᅠ230Vac
  • Useful volume for camera / lens: 2800cm ³
  • Minimum distance between the walls of the housing and the camera/lens: 12mm
Environment
  • For installation indoors and outdoors
  • Operating temperature with heating:ᅠ ᅠ-40°C / +50°C (-40°F/+122°F)
  • Always refer to the temperature in the marking.
Certifications
  • ATEXᅠ ᅠ(EN 60079-0: 2009, EN 60079-1: 2007, EN 60079-31: 2009):
  • Exᅠ ᅠII 2G Ex d IIC T6 Gb

    Exᅠ ᅠII 2D Ex t IIIC T85 °C Db IP66

    ᅠ ᅠ0044:ᅠ ᅠnotify number from competent body

  • IECExᅠ ᅠ(IEC 60079-0: 2007, IEC 60079-1: 2007, IEC 60079-31: 2008):
  • Ex d IIC T6 Gb

    Ex t IIIC T85 °C Db IP66

  • EAC EX:
  • Ex II 2G Ex d IIC T6 Gb,-40°C/+50°C

    EX II 2D Ex t IIIC T85°C Db -40°C/+50°C, IP66

  • KCs 16-KA4BO-0057 -16-KA4BO-0058
  • Ex d IIC T6

    Ex tb IIIC T85°C

Accessories
  • EXHS000 Sunshield 650mm for EXH series
  • EXHS001 Sunshield 760mm for EXHD
  • OEXPLUG3/4 Plug EX 3/4" NPT IECEX-ATEX-EAC Ex
  • OCTEXP3/4C Conduit cable gland nickel-plated brass 3/4" NPT IECEX-ATEX-EAC Ex
  • OCTEX1/2-3/4C Cable glands reduction in nickel-plated brass 3/4" - 1/2" NPT IECEX-ATEX-EAC Ex
  • OCTEXS1/2C Cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable IECEX-ATEX-EAC Ex , ᅠ with gasket from 7.5 to 11.9mm (3 to 4.7in)
  • OCTEX1/2C Cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable IECEX-ATEX-EAC Ex , ᅠ with gasket from 3 to 8mm (0.12 to 0.31in)
  • OCTEXB1/2C Barrier cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable IECEX-ATEX-EAC Ex
  • OCTEXA3/4 Cable gland in nickel-plated brass with gasket EX 3/4" NPT, armoured cable ATEX
  • OCTEX3/4 Cable gland in nickel-plated brass with gasket EX 3/4" NPT, unarmoured cable ATEX
  • OCTEXBA3/4C Barrier cable gland in nickel-plated brass 3/4" NPT, armoured cable IECEX-ATEX-EAC Ex
  • OCTEXB3/4C Barrier cable gland in nickel-plated brass 3/4" NPT, unarmoured cable IECEX-ATEX-EAC Ex
  • OCTEXA3/4C Cable gland in nickel-plated brass with gasket EX 3/4" NPT, armoured cable IECEX-ATEX-EAC Ex
  • OCTEX3/4C Cable gland in nickel-plated brass with gasket EX 3/4" NPT, unarmoured cable IECEX-ATEX-EAC Ex
Brackets and adaptors
  • EXWBJ000 Bracket and ball joint RAL7032 for EXH series
  • EXBJ000 Only ball joint for EXH RAL7032 housings
Spare parts
  • OSLIEXD Internal slide complete with heater for EXHD and EXPTD series
  • OSLIEX Internal slide complete with heater for EXHC and EXPTC series
  • OEXDPVN Complete front flange with glass protection device for EXHD and EXPTD series, RAL7032
  • OEXVETN Complete front flange with glass for EXHC and EXPTC series
  • OEXMYLAR Mylar film replacement kit, 18m (59ft), 350 steps

AVAILABLE MODELS

Available models

Model Number

Housing heater 24Vac

Housing heater 230Vac

Reinforced heater 24Vac

Glass protection device

Environment temperature

EXHC003R

-40°C / +50°C (-40°F/+122°F)

EXHC203R

-40°C / +50°C (-40°F/+122°F)

EXHD005R

-40°C / +50°C (-40°F/+122°F)

TOP