The explosion-protected MAXIMUS MVXT thermal camera is perfect for effective video surveillance and process control in harsh settings where the presence of gases or flammable dust can create a potentially explosive environment, a reality often found in the oil and gas industries or marine and industrial sectors.

The thermal camera is able to detect a person or an object in the most difficult environmental conditions, such us total darkness or other levels of lighting, heavy smoke, rain or dust and across long distances.

One striking advantage offered by these cameras is their extremely easy and secure “plug and play” installation, with multipolar wiring. These cameras arrive ready to use, avoiding the complex electrical connections that are typical of this type of device.

The housing is compact yet functional and is made entirely out of AISI316L stainless steel. Its resistance to corrosion is not only guaranteed, but is also enhanced by way of polishing processes.

Another important feature of the camera is the extended certification temperature range of -60°C to 65°C, along with a sophisticated cold start system, which allows it to operate in harsh environments as standard.

An equally noteworthy point is that the IP66/IP68 ratings guarantee the complete protection against harsh weather and submersion in up to 5 metres of water for 2 hours. Moreover, the IP69 rating allows the device to be cleaned with high pressure water jets.

The MAXIMUS MVX range of cameras meets every installation need, providing maximum performance and excellent value for money.

KEY FEATURES

Certifications for use in Zones 1 and 2, IIC T5 and T6 Group (Gas) and in Zones 21 and 22, IIIC T100°C and T85°C Group (Dust)

Analogue or IP (ONVIF S) versions

Thermal camera:

Sensor: Uncooled microbolometer (VOx)

Lenses: 9mm, 13mm, 19mm, 25mm, 35mm, 50mm

Resolution 336x256 or 640x512

4m (13ft) / 10m (33ft) preinstalled armoured multipolar cable with cable gland or, alternatively, with 4m (13ft) / 10m (33ft) cable tail

Certification temperature:   from   -60°C (-76°F)   up to   +65°C (149°F)

Power supply:   12-24Vdc/24Vac

IP66/IP67/IP68/IP69

TECHNICAL DATA

General
  • AISI 316L stainless steel construction
  • External shot peened and electro-polished surfaces
  • Silicone O-ring seals
  • Configuration via OSM
Mechanical
  • Sunshield
  • Unit weight:
  • 8.5kg (18.7lb)   (housing with 4m multi-polar cable shield)
  • 12kg (26.5lb)   (housing with 10m multi-polar cable shield)
Cable glands
  • Cable entry:   1 hole,   3/4",   NPT
  • Cable gland with gasket Ex d 3/4"NPT and 4m/10m (13ft/33ft) preinstalled multipolar armored cable or with 4m/10m (13ft/33ft) cable tail
Housing's window
  • Germanium window   (big grid)
  • Usable diameter:   57mm
  • Thick:   10mm (0.4in)
  • External treatment:   antiscratch   (Hard Carbon Coating - DLC),   antireflection
  • Internal treatment:   antireflection
  • Spectral range:   from   7.5μm   up to   14μm
  • Medium transmittance   (from   7.5μm   up to   11.5μm):   87.3%
  • Medium transmittance   (from   11.5μm   up to   14μm):   67.3%
  • Germanium window   (small grid)
  • Usable diameter:   40mm (1.6in)
  • Thick:   8mm (0.3in)
  • External treatment:   antiscratch   (Hard Carbon Coating - DLC),   antireflection
  • Internal treatment:   antireflection
  • Spectral range:   from   7.5μm   up to   14μm
  • Medium transmittance   (from   7.5μm   up to   11.5μm):   87.5%
  • Medium transmittance   (from   11.5μm   up to   14μm):   72.1%
Electrical
  • Supply voltage/Current consumption
  • 24Vac,   2.2A,   50/60Hz
  • 24Vdc,   2.2A
  • 12Vdc,   3.5A
  • Heater   (Ton 15°C±3°C (59°F ±5°F),   Toff 22°C±3°C (72°F±5°F))
  • Armoured cable:
  • external diameter   =   20.00 ± 0.50mm (0.79±0.20in)
  • diameter under armature   =   15.20mm (0.60in)
  • colour:   Black   RAL9005
  • Armoured cable composition:
  • 3   x   2.5mm²
  • 7   x   0.34mm²
  • 4 x 2 x 0.22mm²   (IP-based version,   cat. 5E)
  • 1 x coax 75ohm RG179   (analog version)
  • Cable tail composition:
  • 3   x   2.5mm²,   rated external diameter   =   8.7mm (0.34in)
  • 7   x   0.34mm²,   rated external diameter   =   6.4mm (0.25in)
  • 4 x 2 x 0.21mm²,   (IP-based version,   cat. 5E),   rated external diameter   =   6.7mm (0.26in)
  • 1 x coax 75ohm RG59   (analog version),   rated external diameter   =   4.9mm (0.19in)
Network
  • Connector   (only for the IP versions of the product):
  • RJ45,   10BASE-T/100BASE-T
Serial communications
  • Serial interface
  • RS-485 line,   half-duplex
  • Cable length:   1200m   max
  • Addressable units:   255   (configuration via OSM)
  • Serial communication protocol
  • PANASONIC 850:   9600baud,   19200baud
  • PELCO D:   2400baud,   9600baud
  • VIDEOTEC MACRO:   9600baud,   38400baud
Video
  • IP version:
  • Video encoder

  • Communication protocol:   ONVIF, Profile S
  • Device configuration:   TCP/IPv4-IPv6,   UDP/IPv4-IPv6,   HTTP,   NTP,   DHCP,   WS-DISCOVERY,   QoS,   IGMP   (Multicast)
  • Streaming:   RTSP,   RTCP,   RTP/IPv4
  • Video compression:   H.264/AVC,   MJPEG
  • Independent video streams:   2
  • Image resolution:   from Full D1 (720x576 for PAL, 720x480 for NTSC) to 352x240 in 18 steps
  • Web Server
I/O interface
  • I/O alarm board
  • Alarm inputs:   1
  • Relay outputs:   1   (1A,   30Vac/60Vdc   max)
  • Cable length:   200m (656ft)   max   (analog version)
Cameras
  • Power consumption   (assembly,   camera and lens)
  • Without video encoder IP:   8W
  • With video encoder IP:   6W
  • Minimum distance between camera and housing's window:   4mm (0.16in)
  • Cameras dimensions/Lenses that can be installed   (WxHxL)
  • Without video encoder:   70x65x140mm (2,6x2,5x5,5in)
  • With video encoder:   70mmx65mmx120mm
Environment
  • For installation indoors and outdoors
  • Operating temperature:
  • Cold start   from   -40°C (-40°F)   up to   +65°C (149°F)
  • Running   from   -50°C (-58°F)   up to   +65°C (149°F)
  • Relative humidity:   from   10%   up to   95%   (no condensation)
Certifications
  • ATEX   (EN 60079-0: 2012,   EN 60079-1: 2014,   EN 60079-31: 2014)
  • IECEx   (IEC 60079-0: 2011 Ed.6,   IEC 60079-1: 2014-06 Ed.7,   IEC 60079-31: 2013 Ed.2)
  • INMETRO   (ABNT NBR IEC 60079-0:2008 + Errata 1:2011,   ABNT NBR IEC 60079-1:2009 + Errata 1:2011,   ABNT NBR IEC 60079-31:2011)
  • EAC Ex   (TR CU 012/2011)
  • ETL listed for USA (UL 60079-0: Ed: 6, UL 60079-1:Ed:6, UL 60079-31: Ed.2),   cable tail versions
  • ETL listed for Canada (C22.2-60079-0:2015, CSA C22.2-60079-1Ed: 2 CSA C22.2-60079-31Ed: 1),   cable tail versions
  • TYPE 6P,   TYPE 4X   (UL50E)
  • IP69   (EN/IEC60529),   housing only
  • IP66/IP67/IP68   (2   hours,   5m (16ft),   EN/IEC60529)
Accessories
  • OCTEXP3/4C Conduit cable gland nickel-plated brass 3/4" NPT IECEX-ATEX- c CSA us - EAC Ex
Brackets and adaptors
  • NXWBS1 AISI 316L stainless steel wall bracket with joint
  • MHXWFWCA AISI316L stainless steel ball joint
  • NXFWBT AISI 316L stainless steel parapet mounting bracket
  • NXCOL AISI 316L stainless steel pole adapter module
  • NXCW AISI 316L stainless steel corner adapter module