MAXIMUS MPX is an ex-proof PTZ camera that offers a superior image quality and an exceptional precision even in poorly lighted environments. This ex camera is ideal for effective video surveillance and process control in harsh settings where the presence of gases or flammable dust can create a potentially explosive environment. A reality often found in the oil and gas industries or marine and industrial sectors.

The area is always monitored, thanks to the speed and detection accuracy of the target.

MAXIMUS MPX offers maximum resistance against corrosion thanks to construction in AISI 316L stainless steel and micro-shot peened and electro-polished surfaces.

The WASEX washer kit, with tank and pump controlled by an ex-proof solenoid valve, allows flawless and maintenance-free cleaning of the front glass.

The MAXIMUS MPX series products are Lloyd's Register Type Approval System Test Specification Number 1 certified and therefore can be used in Marine and Offshore applications for environmental categories ENV1, ENV2, ENV3 and ENV5 (eg. passenger ships, open-air decks, closed spaces and technical areas that may be subject to heat generated by other equipment, potentially explosive areas, docking procedures).

KEY FEATURES

  • Certifications for use in Zone 1 and 2, Group IIC T6 (Gas), and in Zone 21 and 22, Group IIIC T85° (Dust)
  • Marine Certification: Lloyd's Register Marine Type Approval
  • AISI 316L stainless steel construction, external surfaces micro-shot peened and electro-polished
  • Day/Night camera:
  • True Progressive Scan

    High resolution: up to 550 TV Lines

    Advanced image stabilizer (Stable Zoom Mode)

    Day/Night (Auto ICR: automatic removal of IR filter)

  • Variable speed: from 0.1°/s up to 100°/s Pan and Tilt
  • Position accuracy: 0.02°
  • 2 threaded holes ¾” NPT for use of cable glands or conduit
  • Extremely easy electrical connections directly into the unit, thanks to the explosion-proof inspection box
  • Integrated wiper
  • Operating temperature: from -40°C (-40°F) up to +60°C (140°F)

TECHNICAL DATA

General
  • AISI 316L stainless steel construction
  • External surfaces micro-shot peened and electro-polished
  • Dynamic positioning control system
  • Functions: Autopan, Preset, Patrol, Tour (maximum 3), Autoflip
  • Up to 999 units, addressable by means of dip-switches
Mechanical
  • Cable inputs: 2 x 3/4" NPT
  • Zero backlash
  • Horizontal rotation: 360°, continuous rotation
  • Vertical rotation: from -90° up to +90°
  • Horizontal speed (variable): from 0.1° to 100°/s
  • Tilt speed (variable): from 0.1° to 100°/s
  • Accuracy of preset positions: 0.02°
  • 12mm (0.47in) thick tempered glass window
  • Integrated wiper
  • Unit weight: 26.5kg (58lb)
Electrical
  • Supply voltage/Current consumption
  • 230Vac, 0.5A, 50/60Hz
  • 24Vac, 5A, 50/60Hz
  • 120Vac, 1A, 50/60Hz
  • Power consumption:
  • 120W max
Serial communications
  • Serial communication protocol: AMERICAN DYNAMICS, ERNITEC, PANASONIC, PELCO D, MACRO
  • Maximum number of presets for serial communication protocol
  • MACRO: 250
  • ERNITEC: 250
  • PANASONIC: 250
  • PELCO D: 99
  • AMERICAN DYNAMICS: 95
  • Firmware updating from console in remote mode (PELCO D, MACRO)
  • Configuration through OSM
  • Fiber optic connector: ST (standard)
Video
  • 1 video output 75 Ohm 1Vpp (PAL/NTSC)
  • 16-character string for zone and preset titling
I/O interface
  • I/O alarm board
  • 5 alarm inputs
  • 2 relay outputs (1A 30Vac/60Vdc max)
Environment
  • For indoors and outdoors installation
  • Operating temperature: from -40°C (-40°F) up to +60°C (140°F)
  • Wind resistance
  • PTZ static: 230km/h (143mph) max.
  • PTZ operational at the maximum speed: 210km/h (130.5mph) max.
  • Relative humidity: from 5% up to 95%
Certifications
  • Electrical safety (CE): EN60950-1, IEC60950-1
  • Electromagnetic compatibility (CE): EN61000-6-4, EN61000-3-2, EN61000-3-3, EN50130-4, EN55032 (Class A)
  • RoHS (CE): EN50581
  • Outdoor installation (CE): EN60950-22, ICE60950-22
  • IP protection degree (EN/IEC60529): IP66
  • Vibration test: EN50130-5, EN60068-2-6
  • UL certification (UL60950-1, CAN/CSA C22.2 No. 60950-1-07): cULus Listed (only for 24Vac version)
  • Electromagnetic compatibility (North America): FCC part 15 (Class A), ICES-003 (Class A)
  • Level of protection Type (UL50E): 4X (only for 24Vac version)
  • RCM (Australian and New Zealand Regulatory Compliance Mark)
Certifications - Explosion-proof applications
  • ATEX (EN 60079-0+A11, EN 60079-1, EN 60079-31)
  • IECEx (IEC 60079-0, IEC 60079-1, IEC 60079-31)
  • EAC EX (TR CU 012/2011)
  • INMETRO (ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1, ABNT NBR IEC 60079-31)
  • UL listed for USA (UL 60079-0, UL 60079-1, UL 60079-31), only for 24Vac version
  • UL listed for Canada (CAN/CSA-C22.2 No. 60079-0, CAN/CSA-C22.2 NO. 60079-1, CAN/CSA-C22.2 NO. 60079-31), only for 24Vac version
  • KCs (Employment and labor department 2016-54)
  • Compliant CCEO (PESO)
Certifications - Marine applications
  • Lloyd's Register Marine Type Approval certification (the 24Vac and 120Vac versions require a filter accessory FM1010):
  • Test Specification Number 1 (ENV1, ENV2, ENV3, ENV5)
  • Electromagnetic compatibility: EN60945
  • Salty fog resistance: EN60068-2-52
  • Tested at 70°C (158°F) for 16 hours in compliance with EN60068-2-2
Brackets and adaptors
  • MPXWBA AISI 316L stainless steel wall bracket
  • MPXCW AISI 316L stainless steel corner adapter module
  • MPXCOL AISI 316L stainless steel pole adapter module
  • MPXWBTA AISI 316L stainless steel parapet or ceiling mounting bracket
Accessories
  • WASEX2T4AT Tank 10l (2.6gal) with integrated manual pump controlled by ATEX certified solenoid valve, delivery head up to 20m (66ft) max, IN 24Vac/Vdc
  • WASEX2T4GOR Tank 10l (2.6gal) with integrated manual pump controlled by EAC EX certified solenoid valve, delivery head up to 20m (66ft) max, IN 24Vac/Vdc
  • WASEX2T4IN Tank 10l (2.6gal) with integrated manual pump controlled by INMETRO certified solenoid valve, delivery head up to 20m (66ft) max, IN 24Vac/Vdc
  • MBX1MAA Explosion-proof communication box in stainless steel , IN 230 Vac , with EMC filter for marine certification
  • MBX2MAA Explosion-proof communication box in stainless steel , IN 24 Vac , with EMC filter for marine certification
  • MBX3MAA Explosion-proof communication box in stainless steel , IN 120 Vac , with EMC filter for marine certification
  • MBA1S5A Explosion-proof communication box in aluminium , IN 230 Vac
  • MBA2S5A Explosion-proof communication box in aluminium , IN 24 Vac
  • MBA3S5A Explosion-proof communication box in aluminium , IN 120 Vac
  • OCTEX3/4C Cable gland in nickel-plated brass with gasket EX 3/4" NPT, unarmoured cable IECEX-ATEX-EAC Ex
  • OCTEXA3/4C Cable gland in nickel-plated brass with gasket EX 3/4" NPT, armoured cable IECEX-ATEX-EAC Ex
  • OCTEXB3/4P Barrier cable gland in nickel-plated brass EX 3/4" NPT, unarmoured cable IECEX-ATEX-EAC Ex
  • OCTEXBA3/4P Barrier cable gland in nickel-plated brass EX 3/4" NPT, armoured cable IECEX-ATEX-EAC Ex
  • OCTEX3/4 Cable gland in nickel-plated brass with gasket EX 3/4" NPT, unarmoured cable ATEX
  • OCTEXA3/4 Cable gland in nickel-plated brass with gasket EX 3/4" NPT, armoured cable ATEX
  • OCTEXB1/2C Barrier cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable IECEX-ATEX-EAC Ex
  • OCTEXB1/2P Barrier cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable IECEX-ATEX-EAC Ex
  • OCTEXBA1/2P Barrier cable gland in nickel-plated brass EX 1/2" NPT, armoured cable IECEX-ATEX-EAC Ex
  • OCTEX1/2C Cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable IECEX-ATEX-EAC Ex
  • OCTEXS1/2C Cable gland in nickel-plated brass EX 1/2" NPT, unarmoured cable IECEX-ATEX-EAC Ex
  • OCTEXA1/2C Cable gland in nickel-plated brass EX 1/2" NPT armoured cable IECEX-ATEX-EAC Ex
  • OCTEX1/2-3/4P Cable glands reduction in nickel-plated brass Ex 3/4" - 1/2" NPT IECEX-ATEX-EAC Ex
  • OCTEXP3/4C Conduit cable gland nickel-plated brass 3/4" NPT IECEX-ATEX- c CSA us - EAC Ex ( operating temperature : from -60°C (-76°F) up to +80°C (+176°F) )
  • OCABLMPX4 Cabling for MPX/MPXT, 4m (13ft) (unarmoured cable and barrier cable gland): 2 Ethernet cables, 3 power supply wires, 2 coaxial video cables, 15 wires for alarms, relays and telemetry
  • OCABLMPX10 Cabling for MPX/MPXT, 10m (32.8ft) (unarmoured cable and barrier cable gland): 2 Ethernet cables, 3 power supply wires, 2 coaxial video cables, 15 wires for alarms, relay and telemetry
  • OCABLMPXARM4 Cabling for MPX/MPXHD, 4m (13ft) (armoured cable and barrier cable gland): 1 Ethernet cable, 3 power supply wires, 1 coaxial video cable, 7 wires for alarms, relay and telemetry
  • OCABLMPXARM10 Cabling for MPX/MPXHD, 10m (32.8ft) (armoured cable and barrier cable gland): 1 Ethernet cable, 3 power supply wires, 1 coaxial video cable, 7 wires for alarms, relay and telemetry
  • FM1010 EMC filter for Marine certification

DAY/NIGHT CAMERA

Day/Night 36x

PAL

NTSC

Optical zoom

36x

Wide Dynamic Range (ON, OFF, Auto)

_|SI|_

True progressive SCAN

_|SI|_

Digital image stabilization

_|SI|_

White balance

Auto, ATW, Indoor, Outdoor (Fix/Auto), Sodium Vapor Lamp (Fix/Auto), Manual

High horizontal resolution

Up to 550 TV Lines

Day/Night (Auto ICR)

_|SI|_

Image Sensor

1/4" EXView HAD CCD

Number of effective Pixels

~ 440 000 pixel

~ 380 000 pixel

Min. Lighting Colour (IR-Cut Filter = OFF) (Interlace Mode)

1.4Lux / 1/50s_|n|_0.1 Lux / 1/3s

1.4Lux / 1/60s_|n|_0.1 Lux / 1/4s

Min. Lighting B/W (Interlace Mode)

0.01 Lux / 1/3s

0.01 Lux / 1/4s

“Shutter Time” automatic increase to improve the night surveillance

_|SI|_

S/N ratio

More than 50dB

AE control

Automatic, Shutter priority, Diaphragm priority, Brightness priority and Manual

Back light compensation

On/Off

Spherical masking (3D) of Privacy zones with automatic upgrade

_|SI|_

Privacy Zone Masking

On/Off (24 positions)

Maximum number of masking blocks to be displayed

8

Resolution of masking blocks

160x120 HxV

Masking

Up to 15 different masking types: 14 colour types or mosaic

Focusing system

Auto (Sensitivity: Normal, Low), Trigger PTZ, Manual

“Smart” lens control

Automatic Lens Reset

High Zoom and Wide Horizontal Field of View Capability

_|SI|_

Optical zoom

36x, f=3.4 (wide) to 122.4mm (tele) / F1.6 to F4.5

Digital Zoom

12x (432x with optical zoom)

Horizontal field of view

57.8 degrees (wide) to 1.7 degrees (tele)

Minimum object distance

10mm (0.4in) (wide) to 1500mm (59.1in) (tele)

Shutter speed

1/1 ÷ 1/10 000s