Browse by products

Browse by products

ULISSE EVO THERMALPTZ thermal camera with radiometry functions and high performance

Config link

ULISSE EVO - Witness the Evolution of video security

MARKETS

CERTIFICATIONS

DESCRIPTION

The modern, linear design of ULISSE EVO THERMAL combines maximum strength and operational reliability with greatly reduced weight. This means easy and quick assembly and therefore lower installation costs and zero maintenance. It is designed to guarantee total reliability and continuous operations in the most challenging outdoor environments. It is ultra-resistant to corrosion and can withstand a wide temperature range (from -40°C to +65°C). The extra-sturdy structure is guaranteed by IK10, IP66/IP67/IP68, NEMA TYPE 4X and TYPE 6P protection ratings. Exceptional wind resistance up to 230km/h with PTZ moving at maximum speed.

ULISSE EVO THERMAL has obtained Lloyd’s Register Marine Type Approval for the maritime and shipping sector and complies with the standard for railway applications.

The modern, linear design of ULISSE EVO THERMAL combines maximum strength and operational reliability with greatly reduced weight. This means easy and quick assembly and therefore lower installation costs and zero maintenance. It can even be mounted upside down, in the typical speed domes position. The supports can be supplied with quick-fit connectors for Ethernet/PoE, power supply and I/O. This means the unit can be replaced quickly and easily in case of on-site intervention.

KEY FEATURES

Designed to resist and last

Thermal camera with radiometric functions

Unbeatable solution for outdoor applications

TECHNICAL DATA

General
  • Easy installation thanks to the self-centring connector
  • Zero backlash
  • Quick configuration and setup
  • Dynamic positioning control system
  • Functions: Preset, Preset Tour (Patrol), Autoflip, Autopan via Preset Tour
  • Maximum number of presets: 250
  • Radiometric analysis:
  • on the 4 central pixels, if the thermal camera has radiometric functions
  • definition of a specific area, if the thermal camera has advanced radiometric functions
  • Radiometric alarm activation: If the temperature is over the threshold set, under the threshold set, between two thresholds set or outside the two thresholds set.
  • Actions on alarm: Activation of digital output, preset tour recall, home position recall, preset position recall and http get request.
Mechanical
  • Constructed from aluminium and tecnopolymer
  • Epoxy-polyester powder painted, standard colours RAL9002 or black (RAL9005)
  • Horizontal rotation: 360°, continuous rotation
  • Vertical rotation: from -90° up to +90° (with ceiling installation, from -40° up to +90°)
  • Horizontal speed (variable): from 0.1°/s up to 250°/s
  • Tilt speed (variable): from 0.1°/s up to 250°/s
  • Accuracy of preset positions: 0.05°
  • Cable glands: 2xM16 + 1xM20 + special gasket for RJ45 cables
  • Unit weight: 7.1kg (15.6lb)
Housing's window
  • Germanium window
  • Thick: 1.5mm (0,06in)
  • External treatment: antiscratch (Hard Carbon Coating - DLC), antireflection
  • Internal treatment: antireflection
  • Spectral range: from 7.5μm up to 14μm
  • Medium transmittance (from 7.5μm up to 11.5μm): 91.2%
  • Medium transmittance (from 11.5μm up to 14μm): 80.9%
Electrical
  • Supply voltage/Current consumption:
  • 24Vac ±20%, 5A, 50/60Hz
  • 24Vdc ±10%, 5A
  • PoE 90W (only with OHEP90INJ or OHEP90INJO accessories)
  • ECO-MODE function for energy saving: 21W, P&T static
  • Power consumption:
  • 27W, P&T static, heating switched off
  • 27W, P&T in motion, heating switched off
  • 57W, peak at start-up, heating on and de-icing function
  • Cables input section: from 0.75mm² (18AWG) up to 2.5mm² (13AWG)
  • Cables signal section: from 0.14mm² (26AWG) up to 1mm² (17AWG)
  • Alarm inputs: 2 (auto-powered from 12Vdc up to 18Vdc)
  • Relay outputs: 2 (1A, 30Vac/30Vdc max)
Network
  • Ethernet connection: 100 Base-TX
  • Connector: RJ45
Cybersecurity
  • Digitally signed firmware
  • Password restricted access (HTTP digest)
  • Support of various user access levels
  • Control of accesses IEEE 802.1X
  • HTTPS cryptography using TLS1.0, TLS1.1, TLS1.2 and TLS1.3
  • Centralised certificate management
  • Complies with ONVIF Security Service specifications
Video
  • Video encoder
  • Communication protocol: ONVIF, Profile Q, Profile S and Profile T, ONVIF Thermal Service
  • Device configuration: TCP/IPv4-IPv6, UDP/IPv4-IPv6, HTTP, HTTPS, NTP, DHCP, WSDISCOVERY, DSCP, IGMP (Multicast), SOAP, DNS
  • Streaming: RTSP, RTCP, RTP/IPv4-IPv6, HTTP, Multicast
  • Video compression: H.264/AVC, MJPEG, JPEG, MPEG4
  • 3 independent video streams
  • Image resolution: from 320x180pixel up to 720x480pixel in 4 steps
  • Selectable frame rate from 1 to 30 images per second (fps)
  • Web Server
  • Directional OSD (maximum 4 settable areas)
  • Motion Detection
  • QoS: Differentiated DSCPs for streaming and device management
  • SNMP and NTCIP protocols
Environment
  • For indoors and outdoors installation
  • Operating temperature
  • Continuous functioning: from -40°C (-40°F) up to +65°C (149°F) (+50°C (122°F) for versions painted black)
  • Temperature test complies with NEMA-TS 2-2003 (R2008) par. 2.1.5.1, test profile fig. 2-1 (from -34°C (-29.2°F) to +74°C (165.2°F))
  • De-icing function intervention: from -40°C (-40°F) up to -10°C (14°F)
  • Wind resistance
  • PTZ static: 230km/h (143mph) max.
  • PTZ operational at the maximum speed: 230km/h (143mph) max.
  • Relative humidity: from 5% up to 95%
Certifications
  • Electrical safety (CE): EN60950-1, IEC60950-1, EN62368-1, IEC62368-1
  • Electromagnetic compatibility (CE): EN61000-6-4, EN50130-4, EN55032 (Class A)
  • Outdoor installation (CE): EN60950-22, IEC60950-22
  • IP protection degree (EN60529): IP66, IP67, IP68
  • Salty fog resistance: EN50130-5, EN60068-2-52
  • IK protection degree: IK10
  • UL certification (UL60950-1, CAN/CSA C22.2 No. 60950-1-07,UL62368-1 CAN/CSA C22.2 No. 62368-1-14): cULus Listed
  • Electromagnetic compatibility (North America): FCC part 15 (Class A), ICES-003 (Class A)
  • Level of protection Type (UL50E): 4X, 6P
  • EAC certification
Certifications - Railway applications
  • Compliance to railway application standard: EN50121-4 (the product requires the filter accessory SURGEPR)
Certifications - Marine applications
  • Lloyd's Register Marine Type Approval certification (the product requires the filter accessory FM1010):
  • Test Specification Number 1 (ENV1, ENV2, ENV3, ENV5)
  • Electromagnetic compatibility: EN60945
  • Salty fog resistance: EN60068-2-52
  • Tested at 70°C (158°F) for 16 hours in compliance with EN60068-2-2
TOP