Browse by products
- PTZ cameras and units
- Fixed cameras and housings
- P&T motors
- Cables
- Washing systems
- Illuminators
- Video management
EXHCExplosion-proof housing
MARKETS
CERTIFICATIONS
DESCRIPTION
The EXHC housings are made of a heavy-duty Anticorodal aluminium alloy and are designed to house video cameras installed in explosion-proof environments.
All the external components are powder-painted and guarantee excellent resistance against UV rays, marine environments and any polluting substances in the area of installation.
The cylindrical element of the housing is closed on opposite sides by two flanges and feature two holes for NPT 3/4” cable glands. The video camera housing is equipped with a triple heating element and an optional sunshield.
KEY FEATURES
Designed to meet the strictest international standards and to operate in hazardous areas
Solid, non corrosive die-cast aluminium construction
2 holes for cable glands 3/4" NPT
Ambient temperature: -40°C/+50°C (-40°C/+122°F) with reinforced heater
TECHNICAL DATA
Mechanical
- Non-corrosive die-cast aluminium (anticorodal)
- Epoxy powder painted, RAL9002
- Cable entry: 2 holes, 3/4" NPT
- Internal dimensions: Ø 180x380mm (7.1x15in)
- Internal usable dimensions: 100x100x280mm (3.9x3.9x11in)
- Unit weight:
- 15kg (33.5lb)
Housing's window
- Window with extra clear tempered glass
- Usable diameter: 114mm (4.5in)
- Thick: 12mm (0.47in)
Electrical
- Supply voltage/Current consumption (Ton 15°C±4°C (59°F±7°F), Toff 22°C±3°C (72°F±5°F)):
- 230Vac, 0.3A, 50/60Hz
- 24Vac, 2.5A, 50/60Hz
- Power consumption
- Heater: 60W
- Installable camera: 20W max
Cameras
- Characteristics of installable devices (cameras and lenses):
- Power consumption (assembly, camera and lens): 20W max
- Usable volume for camera/lens: 2800cm³
- Minimum distance between the walls of the housing and the camera/lens: 12mm
Environment
- For indoors and outdoors installation
- Operating temperature with heating: from-40°C (-40°F) up to +50°C (122°F)
- Relative humidity: from 5% up to 95%
Certifications
- Electrical safety (CE): EN62368-1
- Electromagnetic compatibility (CE): EN61000-6-3, EN61000-3-2, EN61000-3-3, EN50130-4, EN55032 (Class B)
- RoHS (CE): EN IEC 63000
- Outdoor installation (CE): EN60950-22, IEC60950-22
- IP protection degree (EN/IEC60529): IP66
Certifications - Explosion-proof applications
- ATEX (EN IEC 60079-0, EN 60079-1, EN 60079-31)
- IECEx (IEC 60079-0, IEC 60079-1, IEC 60079-31)
- EAC Ex (TR CU 012/2011) (pending)
- UK Ex (EN IEC 60079-0, EN 60079-1, EN 60079-31)
For further details on certifications and markings, consult the relevant table.